sugarlanfeng 发表于 2010-12-16 17:19:33

一般修完驱动忙,都会有LBA值为0 ,做下就可以。

ddnxpp 发表于 2010-12-16 20:52:46

试了,看来不行
ASCII Diag mode               

F3 T>/2      

F3 2>Z      

HighPowerMode            
Spin Down Complete                  
Elapsed Time 0.092 msecs                        
F3 2>U      

HighPowerMode            
ExecuteSpinRequest                  

Spin Up Complete               
Elapsed Time 3.746 secs                     
F3 2>/      

F3 T>m0,2,2,0,0,0,0,22                     
Max Wr Retries = 00, Max Rd Retries = 00, Max ECC T-Level = 00, Max Certify Rewr                                                                              
ite Retries = not supported                           

DiagError 0000500D
User Partition Format Failed - Elapsed Time 0 mins 00 secs
R/W Sense 00000002, R/W Error 843200A6, File Error 00000000
Blk Addr 000001510001, Blk Addr Type D0, Cyl FFFF0000, Hd 28

F3 T>/1

F3 1>N1

Init SMART Fail
LED:000000CC FAddr:0024E485

h259108 发表于 2010-12-16 21:04:16

收费可以做

LYN_M 发表于 2010-12-17 16:27:09

典型的led 000000cc ERR

njjon 发表于 2010-12-18 10:38:40

检测不到,尝试复位SMART出错,提示如下:
F3 1>N1
Init SMART Fail
LED:000000CC FAddr:0024E4A3
LED: ...
xintl 发表于 2010-12-16 12:13 http://bbs.intohard.com/images/common/back.gif

有效吗?楼下试过的,回个话

wideview 发表于 2010-12-18 14:56:08

遇到过,但没解决

小杜 发表于 2010-12-19 10:46:01

m,2,6,,,,,22

小杜 发表于 2010-12-19 10:47:03

是7200.11的指令

sqyuanqiang 发表于 2010-12-19 11:07:29

先用M0指令修复LBA=0,然后再在/1>N1修复即可

kwq2000 发表于 2010-12-22 16:17:03

回复 29# sqyuanqiang
页: 1 2 [3] 4 5
查看完整版本: 7200.12 busy 执行N1 显示init smart fail 望高手指点